This estimate is for an attached Alumawood Lattice Pergola kit manufactured by Amerimax Building Products. The rafters will run the projection distance and the lattice will run the length distance. The rafters will be supported by a 3 inch by 8 inch Header Beam and the rafters will hang over the beam. The Header Beam will be supported by posts.
What is included – This kit includes:
 | Cedar Embossed texture (Alumawood) 1-1/2in SQ or 2in SQ Lattice with flat or beveled caps |  | Cedar Embossed texture (Alumawood) 2inx6-1/2in Rafters or 3inx8in Rafters |
 | Cedar Embossed texture (Alumawood) 3inx8in Header Beam |  | Rafter and Header End Caps |
 | Cedar Embossed texture (Alumawood) 3inx3in Posts with 2inx6-1/2in Side Plates |  | 3inx3in Cloverleaf post inserts if steel – 0.041” thick, if aluminum – 0.040” thick |
 | Colonial Post Brackets for Cloverleaf Posts |  | If Selected the kit will include a 3inx8in Steel C Beam – 12 gauge |
 | Lattice Tube End Caps |  | Plastic Hole Plugs |
 | Outside Rafter to Header Brackets |  | Inside Rafter to Header Hanger Brackets |
 | Anchor Bolt Kit |  | Lattice Sheet Metal Screws |
 | Lag Screws if attaching to wall without ledger board |  | Self-Tapping Tek Screws |
 | Sheet Metal Screws |  | Touch-Up Paint - 0.6 oz bottle or 12 oz can depending on kit |
(Ledger board covers, and Corbel or Scallop upgrades may be selected as accessories at check out)
What you provide:
- A wooden Ledger board – (see below)
- Concrete for footings – if applicable (see below)
- Steel bar for reinforcement in footings – if applicable (see below)
- Lag screws or bolts for attaching to a wood deck – if applicable (see below)
ENGINEERING
This Lattice is intended to be attached to a house. This estimate also includes general engineering guidelines that you should adhere to where appropriate.
The engineering for this kit is based off of Amerimax engineering.
| Slope | The minimum slope requirement is 1/2 inch per foot. |
| Wind Load | The wind load for this kit is 90 MPH. This kit is engineered for an exposure B area. This refers to urban or suburban areas, wooded areas, or other terrain with numerous closely spaced obstruction having the size of single-family dwellings or larger. |
| Snow Load | The snow load will be as selected. Snow loads are given in pounds per square foot and range from 10 to 60 PSF. This measurement is also referred to as live load. In most cases even light snow areas will begin at a 20lb load. A 10lb load is for areas that receive no snow. Lattices do have a snow load. |
| Post Spacing | The max post spacing is indicated for each kit in the description. The side overhang (from post to end of header) cannot exceed 25% of the actual post spacing. |
| Length | There is no maximum for length. Length will be as selected in 1 foot increments. This is the length of the lattice and header. |
| Height | This is the distance from the ground to the bottom of the header. In other words this is the post height. |
| Projection | The distance from the house to the end of the rafters |
| Clear Span | The distance from the house to the 3x8 inch Header |
| Overhang | The distance from the 3x8 inch Header to the end of the Rafters |
SUPPORT BEAM AND HEADER TYPES
| 3x8 inch Alumawood Header Beam | This header will be supported by the posts. The rafters will hang over the beam. This beam comes with all kits. |
| 3x8 inch Steel C Beam | If selected this beam will slide into the 3x8 inch Alumawood Header Beam and be concealed from each end with end caps. This beam is constructed of 12 gauge steel and when used with posts into poured footings, is capable of larger snow loads and post spacing. This Beam comes in stock lengths or 20 or 24 feet and may need to be trimmed to fit your needs. |
POST TYPE AND GROUND ATTACHMENT
| Concrete Slab attachments | Awnings that will be attached to a concrete slab will come with Aluminum Cloverleaf posts inserts that are 3 inches by 3 inches and are 0.040 inches thick. They will slide into the Alumawood post to provide extra strength. All hardware and brackets are included for this type of mounting. Remember to keep several inches away from the edge of your slab to avoid cracking your concrete. |
| Wood deck attachment | Awnings that will be attached to a wood deck will come with Aluminum Cloverleaf posts inserts that are 3 inches by 3 inches and are 0.040 inches thick. They will slide into the Alumawood post to provide extra strength. The brackets for a wood deck attachment will be included but the Lag screws or bolts will not be included. Please see Wood Deck Attachment Engineering for appropriate lag screw and bolt descriptions. |
| Footing Attachments | Footings must be poured with a Cloverleaf post being embedded into the concrete. For this reason your quote will indicate a post size that is 2 feet longer than the awning height. This extra 2 feet on the cloverleaf post is intended to be used in the footing. The Alumawood post will slide over the Cloverleaf post. The Alumawood post will not be embedded into the concrete – only the Cloverleaf post. The Cloverleaf post is 3 inches by 3 inches and constructed of 0.041 inch thick steel. No brackets or bolts are needed for the post to footing attachment. Customers must provide the concrete and steel bar for reinforcement for each footing. Each quote with a footing attachment will indicate a footer size. This amount should be cubed for each footing. Please see Footing Engineering for footing details on post depth and steel bar reinforcement. |
HOUSE ATTACHMENT TYPE
| Ledger Board | Engineering requires 2 inch thick ledger boards. For most places a 2x6 or a 2x8 is accepted. Use # 2 Douglas fir or better. Customers are responsible for the ledger board and its attachment to the house. See Ledger Engineering for details. A Ledger Board Cover does not come with this kit but can be purchased separately as an accessory. If ordered the Ledger Boar Cover is to be used as a cover only and not the actual ledger board. Ledger Board Covers are 2 inch by 6-1/2inches and should be filled with the actual ledger board. Most contractor use plywood to fill the remaining void. Ledger Board covers also use the Alumawood cedar embossed texture and will come matching the color selected. The rafters will attach to the ledger board individually using hidden U channel braces, also known as Rafter Hanger Brackets. When a ledger board attachment is selected, 2 inch SMS screws will be sent to attach the hangers. |
| Eave Attachment | Eave attachments require a 2 inch wide fascia. The fascia should be reinforced using Simpson bracket A34 on the back of the fascia to the side of the rafter. Eaves are allowed a certain amount of over hang per snow load and projection. See Eave Engineering for details. The rafters will attach to the fascia individually using hidden U channel braces, also known as Rafter Hanger Brackets. When an eave attachment is selected, 2 inch SMS screws will be sent to attach the hangers. |
INSTALATION
General installation instructions can be found on this site. These are general instructions only and will not cover every situation. Customers are welcome to call Absolute Carports with questions but ultimately customers are responsible for their own installations. It is recommended that customers be familiar and comfortable with tools and assembling. These kits will require cutting and drilling. Parts of this kit may use splices. Extra length is given to parts to aid customers for in field adjustments. A list of needed tools can be found in the General Instruction.
WARRANTY
These products are manufactured by Amerimax Building Products using the latest best practices. We are proud to sell a product that the manufacturer stands behind 100%.
Click here to see product warranty information.
SHIPPING
Allow about 1-1/2 to 2 weeks for manufacturing and about 1 week for shipping. Absolute Carports cannot guarantee a shipping date as these kits are custom manufactured. Kits ship by freight and customers must be present at delivery to unload the product. Customers should receive a phone call by the freight company to verify a delivery time. If damages occur as a result of shipping customers must indicate it on the bill of lading or refuse the product and inform Absolute Carports within 7 days of delivery. All sales are final; products that are refused without damage will not be reimbursed. No returns.